Model |
|
Description |
Price |
|
CS-3230 |
 |
AFM EBox – The EBox includes all of the electronics required to drive an AFM stage, including a Z stepper motor, LL-AFM force sensor and an xyz piezo scanner. The EBox includes LabView applications software for accessing the functions of the electronic board.
|
$13,380.00 |
| |
|
|
|
MS-3230 |
 |
TT-AFM Stage – This stage includes a stepper-motor-driven Z stage, LL-AFM force sensor, and precision X-Y stage. The stage does not include a piezo scanner or video optical microscope. Electrical connections are made at the back of the stage with a 60-pin ribbon cable connector.
|
$13,830.00 |
| |
|
|
|
VM-3230 |
 |
Video Microscope – Included with the video microscope is an illumination source, stand, 3 megapixel CCD camera and visualization software. The resolution of the video microscope is 1.5 microns and it has a working distance of 115 mm.
|
$2,950.00 |
| |
|
|
|
PS-2010 |
 |
50 Micron AFM Scanner – Samples are held in place on this scanner with a removable cap. This modified tripod scanner utilizes low voltage piezoelectric ceramics and temperature compensated strain gauges. Connections to the scanner are made with a 20-pin ribbon cable.
|
$3,280.00 |
| |
|
|
|
XY-2010 |
 |
1” X 1” Precision Stage – Micrometers with .001” resolution are used for generating motion in this X-Y precision stage. The stage has several tapped holes for mounting it onto a platform.
|
$995.00 |
| |
|
|
|
DO-2010 |
 |
Documentation Package for TT-AFM – All of the design documents for the TT-AFM are included with this package. This includes the mechanical drawings for stage components and electronic schematics for the EBox. Purchasing these documents requires signature of a license agreement.
|
$595.00 |
| |
|
|
|
PC-2010 |
 |
Probe Carrier for TT-AFM – A probe carrier holds the probe in the TT-AFM light lever force sensor. The probe carrier includes dither piezo for vibrating mode as well as additional electrical connections.
|
$695.00 |
| |
|
|
|
ZS-2010 |
 |
Z Stage for TT-AFM – High-resolution translation is achieved with this motorized stage. The range of the stage is 1" and the step size is XXX. The stage includes a number of tapped screw holes for mounting.
|
$725.00 |
| |
|
|
|
LA-2010 |
 |
Laser for TT-AFM – This laser module is used in the LL-AFM force sensor. It requires a 5 V power source. The wavelength is 650 nm and it has a focal length of 30 mm.
|
$525.00 |
| |
|
|
|
RE-2010 |
 |
Calibration Reference – A standard reference is required for calibrating an AFM scanner with an optical microscope. This reference includes a pattern that is used for both AFM and optical microscope calibration.
|
$300.00 |
| |
|
|
|
VI-2010 |
 |
Vibration Enclosure – The vibration enclosure helps reduce structural and acoustic vibrations that create unwanted noise in AFM images. This enclosure is recommended for making extremely high resolution images.
|
$1,795.00 |
| |
|
|
|
LI-2011
|
 |
Environmental Cell – Samples may be scanned in liquids as well as inert gases with the environmental cell. The cell replaces the probe holder in the TT-AFM while scanning.
|
$3,325.00
|
| |
|
|
|
PS-2011
|
 |
15 micron scanner – The 15 micron scanner replaces the 50 micron scanner in the TT-AFM. Extremely high resolution scans are made with the 15 micron scanner.
|
$3,280.00
|
|